The final coating for aluminum, galvanized steel or aluminized steel shall be a factory-applied, oven-baked finish based on Kynar 500® polyvinylidene fluoride resin.
This finish shall be a dispersion coating based on Kynar 500 resin as formulated by an Arkema Kynar 500 licensee. This finish shall be in strict accordance with the formulator’s specification and applied by an applicator approved by the formulator. This finish, based on Kynar 500 resin, shall meet the performance criteria of AAMA 2605 specification and be certified by the formulator as containing Kynar 500 resin manufactured by Arkema.
| Components to be Finished |
| Spandrel Panels, Wall Panels, Curtain Walls,
Roofing Systems, Store Fronts, Column Covers,
Entranceways, Louvers, Mullions, Fascia, Highway Signs |
| Performance Requirements |
| Best Durability, Longest Color Life,
Best Corrosion Resistance, Flexibility,
Sand Abrasion, Chemical Resistance |
| Specification |
| AAMA 2605 |
| Components to be Finished |
| Replacement Windows for Retrofit Projects,
High-Rise Apartments, Condominiums, Office Buildings |
| Performance Requirements |
| Better Chalk and Fade Resistance, Longer Life,
Low Maintenance |
| Specification |
| AAMA 2605 |
| Components to be Finished |
| Primary Windows, Doors and Handrails for Institutions,
Condominiums, Commercial Buildings,
Other High-Exposure Areas |
| Performance Requirements |
| Corrosion Resistance, Better Chalk and Fade Resistance |
| Specification |
| AAMA 2605 |
| Components to be Finished |
| Van, Bus and Truck Windows, Tubular Furniture,
Post-Formed Extruded Parts |
| Performance Requirements |
| Color Retention and Chalk Resistance,
Excellent Flexibility |
| Specification |
| AAMA 2605 |
|